When Should Building Control Be Notified? Avoid a Costly Retrospective Mess
November 3, 2026
What Are CDM Regulations? The 2015 Rules Every Client Should Understand
November 4, 2026Almost every house extension needs building regulations approval, and it has to meet several parts of the regulations at once: structure (Part A), fire safety (Part B), damp resistance (Part C), ventilation (Part F), drainage (Part H), safety glazing and guarding (Part K), energy efficiency (Part L) and electrical safety (Part P). The ones that most affect design and cost are foundations, insulation levels, how much glazing you can have, fire escape and any sewer under the footprint.
Building regulations are separate from planning permission. Even if your extension is permitted development, you’ll still need building control sign-off. If you’re new to the topic, our plain-English guide to what building regulations are is a good starting point.
Which parts of the building regulations apply to an extension?
The technical requirements are set out in Schedule 1 of the Building Regulations 2010, with guidance on how to meet them in the government’s Approved Documents. For a typical single or two-storey domestic extension, these are the parts that usually matter:
| Part | Covers | What it means for an extension |
|---|---|---|
| A – Structure | Foundations, walls, beams, roofs | Foundations suited to the ground; steel beams and lintels designed for the loads |
| B – Fire safety | Escape, fire spread | Escape windows to new upstairs rooms; fire-resisting walls near boundaries |
| C – Site preparation and moisture | Damp-proofing | Damp-proof course and membrane linked to the existing house |
| F – Ventilation | Fresh air, extract | Trickle vents in new windows; extract fans in kitchens and bathrooms |
| H – Drainage | Foul and surface water | New drain runs; special approval if you build over or near a public sewer |
| K – Protection from falling, collision and impact | Stairs, guarding, glazing | Safety glass in critical locations; compliant stairs in two-storey extensions |
| L – Conservation of fuel and power | Insulation, heating, glazing | Minimum U-values; a 25% limit on glazed area unless calculations show otherwise |
| P – Electrical safety | Fixed wiring | New circuits must be certified by a registered electrician or checked by building control |
Your building control body will check the plans and inspect at key stages, from the foundation trenches to the final completion.
How well insulated does an extension have to be?
Part L sets maximum U-values (lower is better) for new elements. Council guidance from East Suffolk, Mid Suffolk and Brentwood, based on the version of Approved Document L in force since June 2022, gives these limits for extensions:
| Element | Maximum U-value (W/m²K) |
|---|---|
| New walls (cavity or timber frame) | 0.18 |
| New floors | 0.18 |
| Pitched or flat roofs | 0.15 |
| Windows | 1.4 |
| External doors | 1.4 |
| Rooflights | 2.2 |
These standards are noticeably tighter than before 2022. A new cavity wall, for example, used to be allowed 0.28. In practice that means thicker insulation, which can affect wall thickness, roof build-ups and, sometimes, the internal floor area you end up with.
How much glazing can an extension have?
Under Part L, windows, doors and rooflights are normally limited to 25% of the extension’s floor area, plus the area of any existing openings that the extension covers up. That catches out a lot of people planning bi-fold doors, roof lanterns and glazed gables.
You can go above 25%, but Mid Suffolk and East Suffolk guidance says you’ll then need SAP calculations or an area-weighted U-value calculation, and these usually require better-performing walls, roof or glass to compensate. Get this done at design stage, not after the doors are ordered.
What ventilation and fire safety rules apply?
Ventilation (Part F). Council guidance based on the 2022 Approved Document F says new habitable rooms need background ventilation of at least 8,000 mm² (10,000 mm² in a single-storey dwelling), and an open-plan kitchen-diner needs at least three trickle vents of 8,000 mm² each. Night latches can’t be used instead of trickle vents. Kitchens, bathrooms and utility rooms also need mechanical extract.
Fire safety (Part B). New habitable rooms on the first floor of a house normally need an escape window. Building control guidance based on Approved Document B gives the typical requirement as an unobstructed openable area of at least 0.33 m², with no clear dimension under 450 mm, and the bottom of the opening no more than 1,100 mm above the floor. Walls close to a boundary may also need to resist fire spread, which can limit windows on that side.
What if there’s a sewer or drain where I want to build?
This is one of the most common hold-ups in Essex and Suffolk. Many shared household drains are public sewers owned by Anglian Water. Ipswich Borough Council’s guidance says extensions over or close to a mapped sewer must comply with Requirement H4, that Approved Document H advises against building over a manhole or access point on a sewer serving more than one property, and that the council can’t approve the work until Anglian Water has been consulted and issued an agreement.
Ipswich’s guidance also says you can’t use a building notice for work over or near a public sewer, so you’ll need a full plans application. Sewers less than two metres deep may need bridging and protecting, and foundations may need extending locally. A drainage survey early on saves surprises, and it’s routine work for our drainage team.
Do I need full plans or a building notice for an extension?
For most extensions, a full plans application is the safer route. The design is checked before you start, which matters when there are steel beams, glazing calculations or drains involved. A building notice can work for simple projects, but you take the risk of having to change work on site. Our guide to building notice vs full plans covers the trade-offs, and when building control should be notified explains the notices you’ll need once work begins.
Foundations deserve special mention locally. Much of north Essex is on clay, and the depth and design of foundations depend on the soil and on nearby trees, so your building control inspector will want to see the trenches before concrete goes in. That’s why careful groundworks are the base of every good extension.
Frequently asked questions
Do I need building regulations for a single-storey extension?
Yes, in almost all cases. Some small conservatories and porches at ground level can be exempt, but not if they have fixed heating or aren’t separated from the house by external-quality walls and doors.
Can I have a fully glazed extension?
Possibly, but going above the 25% glazing limit needs calculations to show the extension still meets Part L overall, which usually means higher-spec glass or more insulation elsewhere.
Does the existing house need upgrading too?
Sometimes. Council guidance notes that extending the heating system may mean checking the boiler’s efficiency, and an upgrade may be required. Any existing walls or windows you alter must not be made worse.
Who arranges building regulations approval?
Usually your designer or builder submits the application, but the property owner is ultimately responsible for making sure the work complies. Agree who’s doing what before work starts.
Planning an extension in Essex or Suffolk?
CJC Contracts is a Colchester-based building and groundworks contractor, established in 2007 and based in Great Horkesley, working across Essex and Suffolk. We build extensions to building regulations from the foundations up and work alongside your designer and building control throughout. For a free quote, get in touch online or call 01206 273689.